Wednesday, 22 January, 2025

02 Oct 2013 | Press Release

news > News and Events > Page 1

New Straumann implants reduce treatment invasiveness

New Products

Straumann today announced that it is introducing Roxolid SLActive implants in a new range of sizes that help dental professionals to avoid bone augmentation procedures, saving patients trauma, discomfort, time and money.


The key to the new implants is the unique material Roxolid, which is considerably stronger than pure titanium,1 the most widely-used dental implant material. Furthermore, in combination with the SLActive surface, Roxolid has demonstrated superiority to other high-strength materials with regard to osseointegration in a preclinical trial.2

Since its initial market launch at the end of 2009, Roxolid has been introduced in most major markets but only with Straumann 3.3mm implants, which are designed for use in narrow spaces or where limited bone is available. Experience gained in an extensive clinical program, has provided the basis for Straumann to supply all its implants in Roxolid with the goals of minimizing invasiveness and making treatment possible for patients with insufficient bone. Consequently, Straumann Soft Tissue Level and Bone Level Implants are now available in Roxolid in 3.3, 4.1 and 4.8 mm diameters. All feature the SLActive surface for accelerated osseous healing and all feature the new Loxim Transfer Piece for easier handling.

New short implant
Straumann is also launching a new short implant, which is just 4 mm in length - making it the company's smallest implant. This implant has been evaluated for more than 5 years in a clinical trial3 and has shown excellent performance. Designed to avoid extensive augmentation procedures in patients with insufficient vertical bone for conventional implants, the new implant is available in Europe, Australia and New Zealand, in a soft tissue level design and in 4.1 mm and 4.8 mm diameters. Introductions in North America and elsewhere are planned and will follow regulatory clearances.

The need for a new material
Pure titanium is well known for its biological compatibility with the human body, its ability to integrate with bone, its resistance to corrosion, and its strength. However, its mechanical properties are limited in the case of small diameter implants or components. This prompted the search for alternatives that offered biomechanical strength with unimpaired osseointegration. Roxolid is an alloy of titanium and zirconium, the only two metals commonly used in implantology that have been shown not to inhibit the growth of osteoblasts, the bone-forming cells that are essential for osseointegration.4 In contrast to other alloys, Roxolid can be combined with Straumann's SLActive surface technology, which enhances osseous healing. Roxolid thus combines high tensile and fatigue strengths with excellent osseointegration and has been designed to increase reliability and confidence with small diameter implants.5,6,7,8

Backed by one of the most extensive clinical programs
For more than 5 years, Roxolid has been undergoing a broad program of clinical and pre-clinical trials. With 17 publications, including 8 published clinical studies and 9 preclinical studies this is one of the largest research programs ever undertaken by a dental implant company. The trials include double-blind randomized controlled studies and Non-Interventional-Studies to assess the performance of Roxolid implants in daily practice. Implant performance in narrow spaces and in the anterior region have also been investigated.

In general, success and survival rates have been extremely high. For instance, in a multicenter study6 of Roxolid small diameter implants, the survival rate was 99% at 3 years. Furthermore, the average crestal bone loss reported is minimal.

Loxim - perfecting handling
In recent years Straumann has worked hard to perfect implant handling, adding convenience with uncompromised precision and reliability. Roxolid SLActive implants are supplied with Loxim, a new transfer piece that detaches faster and easier from the implant after placement in the patient - making the surgeon's job easier. Loxim requires an exceptionally high standard of precision and was developed in collaboration with an international team of expert dental surgeons from different practice settings and universities.

Roxolid SLActive implants are now available in Europe, North America, Australia and New Zealand, both as bone or soft tissue level options. Further markets will follow pending regulatory approvals.

More about Roxolid: www.straumann.com/roxolid

References
1. Compared with grade 4 annealed (specifications from standard ASTM F67) and cold-worked titanium (data on file).
2. Saulacic N, Bosshardt DD, Bornstein MM, Berner S, Buser D: Bone apposition for a titanium-zirconium alloy implant as compared to two other titanium-containing implants. Eur Cell Mater 2012; 23:273-286.
3. Slotte Christer et al, Four-mm implants supporting fixed partial dentures in the posterior mandible. 5-year results from a multicenter study . Presented at the 20th Annual Scientific Meeting of the European Association of Osseointegration, 10-13 October 2012, Copenhagen, Denmark.
4. Steinemann SG. Titanium - the material of choice? Periodontol 2000. 1998 Jun;17:7-21.
5. Barter S, Stone P, Bragger U.: "A pilot study to evaluate the success and survival rate of titanium-zirconium implants in partially edentulous patients: results after 24 months of follow-up." Clin Oral Implants Res. 2012 Jul;23(7):873-81.
6. Al-Nawas B, Bragger U, Meijer HJ, Naert I, Persson R, Perucchi A, Quirynen M, Raghoebar GM, Reichert TE, Romeo E, Santing HJ, Schimmel M, Storelli S, ten Bruggenkate C, Vandekerckhove B, Wagner W, Wismeijer D, Mueller F.: A double-blind randomized controlled trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV small-diameter bone level implants in edentulous mandibles--results from a 1-year observation period. Clin Implant Dent Relat Res. 2012 Dec;14(6):896-904.
7. Benic GI, Gallucci GO, Mokti M, Hammerle CHF, Weber H-P, Jung RE: Titanium-zirconium narrowdiameter versus titanium regulardiameter implants for anterior and premolar single crowns: 1-year results of a randomized controlled clinical study, J Clin Periodontol. 2013 Aug 14. Epub ahead of print.
8. Gottlow J, Dard M, Kjellson F, Obrecht M, Sennerby L. Evaluation of a new titanium-zirconium dental implant: a biomechanical and histological comparative study in the mini pig. Clin Implant Dent Relat Res. 2012 Aug;14(4):538-45.

Related Contacts

Clinical

Clinical

The Cutting Edge

Abstracts

Stream the latest dental videos...
Expert talk: Freedom in movement

Sponsored Links...

Upcoming Events...

Jan 01 2025
Feb 06 2025
Feb 07 2025
Feb 12 2025
Feb 18 2025

Siberian Dental Forum 2025

Krasnoyarsk, RUSSIA

Feb 27 2025

Maximising Recall Compliance

Live Online, AUSTRALIA

Feb 28 2025
Mar 04 2025
Mar 12 2025
Mar 15 2025
Mar 19 2025

ITI Congress Colombia

Bogota, COLOMBIA

Mar 21 2025
Mar 21 2025

ITI Congress UK & Ireland

Birmingham, UNITED KINGDOM

Mar 22 2025
Mar 24 2025
Mar 25 2025

IDS 2025

Cologne, GERMANY

Mar 29 2025
Apr 02 2025
Apr 10 2025
Apr 12 2025

ITI Congress Southern Africa

Cape Town, REPUBLIC OF SOUTH AFRICA

Apr 15 2025
Apr 15 2025
May 01 2025
May 08 2025
May 12 2025
May 22 2025

ICOMS 2025

Singapore, SINGAPORE

May 23 2025

Famdent Show Mumbai 2025

Mumbai, INDIA

May 26 2025
May 28 2025
May 30 2025
May 30 2025
Jun 07 2025
Jun 09 2025
Jun 11 2025
Jun 21 2025
Jun 25 2025
Jun 27 2025

ICOI Asia Pacific Congress 2025

Deagu, KOREA, SOUTH

Sep 13 2025
Sep 20 2025
Oct 16 2025

ADOHTA-DHAA 2025 National Congress

Gold Coast, AUSTRALIA

Mar 20 2026
Apr 17 2026

IDEM Singapore 2026

Singapore, SINGAPORE