Saturday, 17 May, 2025

31 Jul 2019 | Australasian Dental Practice

news > Spectrum > Page 40

Carestream Dental CS 3600 intraoral scanner tested to have highest accuracy in latest implantology study

When it comes to placing implants, accuracy matters and the CS 3600 intraoral scanner was found to give the most accurate results during a new study, Trueness and Precision of Five Intraoral Scanners in the Impressions of Single and Multiple Implants: A Comparative In-Vitro Study.1


With few peer-reviewed studies evaluating the clinical efficacy of intraoral scanners in implantology, these latest findings from Drs Francesco Guido Mangano, Uli Hauschild, Giovanni Veronesi, Mario Imburgia, Carlo Mangano and Oleg Admakin compared the trueness and precision of five intraoral scanners and determined which have both accurate and consistent results.

According to the study, the CS 3600 had the best accuracy, while having the fewest "triangles" making up the meshes in all applications.

"The number of triangles is often misinterpreted to be a measure of acquisition resolution or mesh quality," Victor Wong, PhD, director, research and innovation, Carestream Dental, said. "In fact, by having the best trueness with the smallest number of triangles, the CS 3600 demonstrates the most efficient/optimal mesh generation by placing more triangles in areas with more details and vice versa, with minimised mesh file size while maintaining accuracy."

To put the scanners to the test, 10 scans were performed by a single digital dentistry expert per indication per intraoral scanner with a zig-zag technique in the same environmental conditions. Two maxilla plaster models were used as a reference: One partially edentulous and one fully edentulous.

In this study, trueness is defined by the difference between the scanned model and the reference model; precision is quantified by the difference between repeatedly scanned models. In both cases, smaller values indicate greater trueness and/or precision. A scanner needs both trueness and precision to be considered accurate.

When scanning a single crown, the CS 3600 was found to have the best trueness (15.2 ±0.8 μm) and the best precision (11.3 ±1.1 μm). The CS 3600 also had the best trueness (23 ±1.1 μm) and the best precision (21 ±1.9 μm) when scanning a partial prosthesis. While scanning a full arch, the CS 3600 had the best trueness (44.9 ±8.9 μm) and had the second-best precision (35.7 ± 4.3), which very closely follows the best precision result (35.6 ± 3.4).

This is not the first time that studies have confirmed the CS 3600's high performance. In a 2018 study,2 the CS 3600 outperformed other scanners, as well as traditional impressions in finish line accuracy. Its trueness was confirmed by a 2017 study that tested the accuracy of four intraoral scanners in oral implantology.3

References

  1. Mangano F, Logozzo S, Hauschild U, Veronesi G, Imburgia M, Mangano C, Admakin O. June 6, 2019. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC Oral Health. 19(101): DOI 10.1186/s12903-019-0792-7.
  2. Nedelcu R, Nystrom I, Olsson P, Thor A. Feb. 26, 2018. Finish Line Distinctness and Accuracy in 7 Intraoral Scanners versus Conventional Impression: An In-vitro Descriptive Comparison. BMC Oral Health.18(27): DOI 10.1186/s12903-018-0489-3.
  3. Imburgia M, Logozzo S, Hauschild U, Veronesi G, Mangano G, Mangano FG. June 2, 2017. Accuracy of Four Intraoral Scanners in Oral Implantology: A Comparative In-Vitro Study. BMC Oral Health. 17(92): DOI 10.1186/s12903-017-0383-4

Mouth Wide Shut

Staying Safe

Management

Techniques

Stream the latest dental videos...
COVID-19 update: 16 March 2020

Sponsored Links...

Upcoming Events...

Jan 01 2025
May 15 2025

NCDS 2025

Myrtle Beach, USA

May 16 2025

BDA 2025

Birmingham, UNITED KINGDOM

May 20 2025

GalMED 2025

Lviv, UKRAINE

May 21 2025

Dentima Krasnodar 2025

Krasnodar, RUSSIA

May 22 2025

C.O Life Summit

Barranquilla, COLOMBIA

May 22 2025

ICOMS 2025

Singapore, SINGAPORE

May 23 2025

Famdent Show Mumbai 2025

Mumbai, INDIA

May 26 2025
May 28 2025
May 28 2025

Buldental - Bulmedica 2025

Sofia, BULGARIA

May 29 2025

CUSCO 2025

Urubamba, PERU

May 30 2025
Jun 03 2025
Jun 07 2025
Jun 09 2025
Jun 10 2025

PACK EXPO Southeast 2025

Guadalajara, MEXICO

Jun 11 2025
Jun 18 2025
Jun 20 2025

Scottish Dental Show 2025

Glasgow, UNITED KINGDOM

Jun 21 2025
Jun 25 2025
Jun 27 2025

ICOI Asia Pacific Congress 2025

Deagu, KOREA, SOUTH

Jul 22 2025
Aug 01 2025
Aug 07 2025
Aug 07 2025

IndoHealthcare Expo 2025

Jakarta, INDONESIA

Aug 22 2025

HKIDEAS 2025

Hong Kong, HONG KONG

Aug 28 2025

ABSO Meeting 2025

Hamilton Island, AUSTRALIA

Sep 03 2025

AAPD 2025

Kuta, INDONESIA

Sep 09 2025
Sep 11 2025

Veneers: A Comprehensive Guide

Auckland, NEW ZEALAND

Sep 12 2025
Sep 13 2025
Sep 17 2025

PharMed Cambodia 2025

Phnom Penh, CAMBODIA

Sep 19 2025
Sep 20 2025
Sep 25 2025
Sep 29 2025

PACK EXPO Las Vegas 2025

Las Vegas, USA

Oct 02 2025

IAO 2025

Padova, ITALY

Oct 02 2025

ITI Congress Brazil

Rio de Janeiro, BRAZIL

Oct 09 2025

Pragodent 2025

Prague, CZECH REPUBLIC

Oct 15 2025
Oct 16 2025
Oct 16 2025

DDS Global Congress 2025

Venice, ITALY

Oct 16 2025

OHAA 2025 National Congress

Gold Coast, AUSTRALIA

Oct 24 2025
Nov 05 2025

ITI Congress Mexico

Mérida, MEXICO

Nov 06 2025
Nov 07 2025

ITI Congress Italy

Bologna, ITALY

Nov 08 2025

CDSS 2025

Singapore, SINGAPORE

Nov 14 2025

IDEC 2025

Jakarta, INDONESIA

Nov 20 2025
Nov 28 2025
Dec 05 2025

8th Dental Expo 2025

Lahore, PAKISTAN

Mar 20 2026
Apr 17 2026

IDEM Singapore 2026

Singapore, SINGAPORE

Nov 27 2026
Nov 26 2027
Nov 24 2028